Video Source Setup (no video from VCR HDMI input)
In rmware v2.24 and previous issues, the VCR input is by default assigned to the composite video input and should be reassigned to the HDMI input by opening the
Input cong menu under the VCR heading and setting the Video source to HDMI. e default for ALL video inputs is HDMI for rmware versions later than v2.24
Green line on the side of the screen
In several cases, this has been shown in several cases to be due to the EDID information from the display requesting an incorrect sync polarity which shis the image.
Types of displays showing this should be reported to the manufacturer and Arcam. is may be overcome on most panels/projectors by selecting the Overscan option
(screen zoom between 2 and 5%) on some Sony panels this is assigned per input.
Flicker on-screen or screen goes blank when selecting to play a Blu-ray from the navigation menu
is is due to the display device relocking to a dierent frame rate usually a transition from 1080p 60 to 1080p 24 – this is perfectly normal and an action of the panel/
projector relocking to the new frame rate.
HDMI video output setup (very important)
e default video output resolution setting is preferred. Many displays still request 1080i as their preferred resolution. If this is the case, a 1080p 24fps source will
result in no video. To correct this, change the output resolution from preferred to 1080p.
e default output frame rate is auto, which will only output frame rates the display indicates it is capable of in its EDID. Some displays do not indicate they can
handle 24fps signals in their EDID. If this is the case, then changing the output resolution to follow input will force a 24fps for such a source.
Unable to set the source blu-ray player to 24fps
In some circumstance certain brands of blu-ray player may show the 24fps setting option as grayed out or unelectable this may be caused by the player not re-reading
the EDID back from the display device – in this instance you should.
1. Physically disconnect the HDMI cable and then reinsert at the Blu-ray players output.
2. Connect the player directly to the panel just for calibration of the 24fps setting.
Use of 3D material
To switch 3D material via the AVR400 you must set the Video Outputs set up to BYPASS as seen under the HDMI output resolutions drop down options
Viera Link
It would appear that many Panasonic source devices such as Bluray/set top products have as default Viera link set to on – this may cause the player to ignore your
specied output resolution aer a standby cycle i.e you have adjusted the output resolution and moved from auto to 1080p aer standby cycle the player has reverted
to 1080i or another resolution – ensure that Viera link is switched o to cure this issue.
Switching of 3D video source material
If installing a 3D capable version of the AVR600/AV888 you must set the product to Video BYPASS. is option is found within the Video Output Resolution
settings. Please note video Bypass is only available on Output 1.
Changing Video output resolution from remote
Simply press the AMP button on the remote follow by Shi then within 1 sec press the Right arrow – you will see the current resolution display –press Shi and the
Right arrow again and the AVR will move to the next resolution.
Bypass of HDMI in standby
HDMI bypass when the unit is in standby (3D models) is not possible due to the HDMI PCB being powered down to save power.
Use of analogue video inputs
As above the installer must reassign the relevant video path from the HDMI default within the input cong video source – options are (HDMI, Component, s-Video,
Composite)
23425 AVR360/400 — FAQ
Part 2 -Video
Intermittent short term drop of video or total lack of video.
During movie playback (usually) at 1080p, and (3D models) if the video is present with the menu up, but not in bypass, this can be an indication that the data received
by the panel projector is on the edge of usability – try substituting the output cable if this is the longest run – if not try the input cable.
Also conrm the cable is capable of carrying high speed signals. In some older installations where existing cables are used to carry 1080i/720p signals these cables
may need to be replaced with high speed cables capable of 1080p/24 operation or in the case of 3D certied High Speed cables.
Remember HDMI cables become an integral part of the whole system not only sending video/audio signals but the all important HDCP protocol data.
Page view 1
1 2 3 4 5 6 7

Comments to this Manuals

No comments