Arcam AVR400 User Manual Page 19

  • Download
  • Add to my manuals
  • Print
  • Page
    / 30
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 18
19
Balance (0x3B)
Adjust the balance control.
Example
Command/response sequence to set the balance to -3:
Command: 0x21 0x01 0x3B 0x01 0x83 0x0D
Response: 0x21 0x01 0x3B 0x00 0x01 0x83 0x0D
Dolby Pro Logic II Dimension (0x3C)
Adjust the ‘Dimension’ parameter of the Dolby Pro Logic II processor.
Example
Command/response sequence to set the dimension to -1:
Command: 0x21 0x01 0x3C 0x01 0x81 0x0D
Response: 0x21 0x01 0x3C 0x00 0x01 0x81 0x0D
Dolby Pro Logic II Centre Width (0x3D)
Adjust the ‘Centre Width’ parameter of the Dolby Pro Logic II processor.
Example
Command/response sequence to set the centre width to 3:
Command: 0x21 0x01 0x3D 0x01 0x03 0x0D
Response: 0x21 0x01 0x3D 0x00 0x01 0x03 0x0D
COMMAND:
Byte: Description:
St 0x21
Zn Zone number
Cc 0x3B
Dl 0x01
Data 0x00 — 0x06 – Set the balance to 0 — 6
0x81 — 0x86 – Set the balance to -1 — -6
0xF0 – Request current balance
0xF1 – Increment the balance by 1dB
0xF2 – Decrement the balance by 1dB
Et 0x0D
RESPONSE:
Byte: Description:
St 0x21
Zn Zone number
Cc 0x3B
Ac Answer code
Dl 0x01
Data1 0x00 — 0x06 – Balance is 0 — 6
0x81 — 0x86 – Balance is -1 — -6
Et 0x0D
COMMAND:
Byte: Description:
St 0x21
Zn Zone number
Cc 0x3C
Dl 0x01
Data 0x00 — 0x03 – Set the Pro Logic II Dimension parameter to 0 — 3
0x81 — 0x83 – Set the Pro Logic II Dimension parameter to -1 — -3
0xF0 – Request current Pro Logic II Dimension setting
0xF1 – Increment the Pro Logic II Dimension
0xF2 – Decrement the Pro Logic II Dimension
Et 0x0D
RESPONSE:
Byte: Description:
St 0x21
Zn Zone number
Cc 0x3C
Ac Answer code
Dl 0x01
Data1 0x00 — 0x03 – The Pro Logic II Dimension parameter is 0 — 3
0x81 — 0x83 – The Pro Logic II Dimension parameter is -1 — -3
Et 0x0D
COMMAND:
Byte: Description:
St 0x21
Zn Zone number
Cc 0x3D
Dl 0x01
Data 0x00 — 0x07 – Set the Pro Logic II Centre Width parameter to 0 — 7
0xF0 – Request current Pro Logic II Centre Width setting
0xF1 – Increment the Pro Logic II Centre Width
0xF2 – Decrement the Pro Logic II Centre Width
Et 0x0D
RESPONSE:
Byte: Description:
St 0x21
Zn Zone number
Cc 0x3D
Ac Answer code
Dl 0x01
Data1 0x00 — 0x07 – The Pro Logic II Centre Width parameter is 0 — 7
Et 0x0D